Taylor Sulfuric Acid 16oz
Taylor Sulfuric Acid 16oz
Taylor R-0009-E Sulfuric Acid; 16oz
Keeping your pool water clean and well balanced is key to protecting your pool, and anyone swimming in it. Test your pool water 2-3 times per week for the perfect swimming environment.
- For use as directed with Taylor Technologies test kits
- Specifically for use with Taylor Technologies swimming pool test kits. Use for any other purpose is not recommended.
PureFilters - Canada's Top Pool Supply company
We deliver affordable pool filters & pool supplies directly to your door to save you time and money. This allows you to focus on what really matters - enjoying your pool. Quality products, fast delivery, and reliable customer service, is what makes PureFilters one of Canada's top pool suppliers in Canada. If you need help placing an order, feel free to reach out via our live chat or at support@purefilters.ca.
Taylor R-0009-E FAQs
What is the Taylor R-0009-E sulfuric acid reagent used for?
Taylor R-0009-E is a 16 oz (pint) bottle of Sulfuric Acid .12N, Taylor's Reagent #9 for the total alkalinity test. A 25 mL water sample is treated with R-0007 and R-0008 until it turns green, then R-0009 is added one drop at a time until it turns red. Each drop equals 10 ppm total alkalinity.
Which Taylor test kits use R-0009 sulfuric acid?
Taylor R-0009 is the alkalinity titrant in the Taylor K-1004 6-Way Test Kit and in Taylor's Complete kits, the K-2005 and K-2006 and their salt versions. All of them use the same drop test, where each drop of R-0009 that turns the sample from green to red counts as 10 ppm total alkalinity.
How do I test high alkalinity with Taylor R-0009?
For high readings, Taylor's instructions for R-0009 use a smaller 10 mL sample with 1 drop of R-0007 and 3 drops of R-0008, then R-0009 added drop by drop until the sample turns from green to red. Multiply the number of R-0009 drops by 25, instead of 10, to get total alkalinity in ppm. Taylor's ideal range is 80 to 120 ppm.
Can I use Taylor R-0009 to clean my test kit comparator?
Yes. Taylor recommends R-0009 sulfuric acid for removing residue from comparator test cells: fill the cell with water, add a couple of drops of R-0009, scrub with a bristle brush, then rinse the comparator well. Taylor also suggests replacing comparators every 2 to 3 years, depending on how often they are used.
How long does Taylor R-0009-E reagent last?
Taylor prints an expiration date and lot number on the R-0009-E label; replace the reagent once it passes that date, and Taylor's kit instructions advise replacing reagents once a year or each season. Store it between 2 and 29°C (36 to 85°F), out of direct sunlight, away from pool chemicals and tightly capped.
What is the difference between Taylor R-0009-E and R-0009-C?
Taylor R-0009-E and R-0009-C are the same Sulfuric Acid .12N reagent (Reagent #9 for total alkalinity) in different sizes. R-0009-E is the 16 oz pint size, while R-0009-C is the 2 oz dropper bottle. PureFilters also carries the Taylor R-0009-C 2 oz sulfuric acid.